banner



Uxcell Usb-ppi Plc Programming Cabe Usb to Rs485 Adapter for Siemens S7-200 Driver Software Download Updated FREE

Uxcell Usb-ppi Plc Programming Cabe Usb to Rs485 Adapter for Siemens S7-200 Driver Software Download

USB Cable Drivers

FTDI / Prolific / SiLabs / WCH


Microsoft
(tm) Drivers

May 2013, 2015, 2019
Rev  seven/2020

John  K3NXU   Jim  KC9HI

Of import Notes - Read First

Your programming cable Must have the correct commuter installed to interface with your computer. Some disquisitional notes:
-  Not all cables load the right driver automatically.
-  Not all provided CDs come with the correct drivers.
-  Cablevision drivers are not interchangeable

Past using Windows Device Director, yous should easily be able to determine which flake is in your programming cable.

FTDI chipsets
Cables with FTDI chipset (FT232R) will automatically download the right driver when inserted into the USB port.

  WCH chipset
Many Baofeng and generic programming cables are shipping with the WCH chipset (CH340/341). The driver should also download automatically. If not, the commuter and procedure can be found at this Link.

  SiLabs chipset
Drivers for the Silicon Labs chipset (CP210x) should besides download automatically. If not the driver can be plant at this Link.

Prolific Chipset
Virtually every programming cable that is detected by Windows every bit having a Prolific chip was manufactured with an unauthorized or cloned copy of the Prolific PL2303HXA chip. The latest driver installed by Windows (Vista, 7, 8.1 and 10) is not compatible with these fries. The last compatible Prolific commuter was v3.3.ii.105 [27/10/2008]. Windows may attempt to automatically load the Prolific commuter three.6.xx.30 when inserting your cablevision. When opening Device Director, the Yellow Caution Triangle may non appear, however, when the cable is inserted into the radio, the transmitter volition plough on. This should not occur. It was done to prevent use of the cloned flake.  More detail tin be found Here.
If this occurs, you Must backdate your driver to three.2.0.0
(Get direct to Install Drivers)

  Windows Device Manager

If Windows does not automatically load the proper commuter, a circumspection bulletin will appear in Device Director. Example shown here is for a WCH340 chip.

  Notation: If y'all recently upgraded to Win10 and the V3.ii.0.0 driver was previously installed on your computer, you volition just need to select it again. See step 7 in the "Installing the Backdated Prolific PL-3203 Driver" department below.


Prolific Driver 3.2.0.0 recommended for Vista, Win7/eight/10
iii.two.0.0 exe     iii.ii.0.0 cipher   (32/64 chip)

-
XP:
If you are using Win XP, the Prolific driver 2.0.ii.1 will run with no problems. This commuter for Win XP can exist plant here: 2.0.2.1.zip


-
MacOS

The recommended Drivers and Info can be plant at the bottom of this page.

     FAQs and Error Letters

     Determine what Cable I have

                Installing the proper Commuter 3.2.0.0

     MacOS - Drivers and Info Below                YouTube Video describing the Process


 

What UART chip does my cable accept ?
Do I Accept the Proper Windows driver ?

1) Insert your USB Programming Cable.

2)

Launch Device Manager.

     [  Beginning  |  Right-click Computer  |  Select Properties  |  Device Manager  ]


Failure


3) Select: Ports (COM & LPT)

Failure


It is recommended that the driver be backdated to iii.2.0.0 if:

A - A yellow warning triangle appears nether 'Ports' or 'Other Devices'
B - The Prolific 'Phased Out' message appears


Also,
if you insert your programming cable into your radio, and the transmitter turns on, you lot volition need to load the backdated driver three.2.0.0 as described below.


Notation:
        Your software will inquire for this Com Port number later.
If you change USB ports, the Com Port number will as well change.

Success


Note:
If Device Manager does Non say "Prolific",
Stop here .

There are several USB Driver chipset manufactures.
SiLabs, FTDI, WCH
The 'Prolific' drivers will not work with these chipsets.


Installing the Backdated Prolific PL-2303 Driver 3.2.0.0

Organization Requires 32/64 chip  Windows Vista / 7 / 8 / 10

1) Create a piece of work folder (New Folder) on your PC.

2) Download the Prolific three.two.0.0 driver file and salve it to the work folder.

3) Remove the USB programming cablevision from your PC.

4) Double-click the file that was saved into the piece of work folder and follow the prompts until it is completely installed.

v) Plug the USB programming cablevision into the USB port of your PC.
You should come across a balloon popup that says "Installing device driver software"

Installing Device Driver

A few seconds later on you lot volition get a balloon popup that says
"Device driver software was not successfully installed"

Installing Device Driver

6) Launch Device Manager.

          [  Start  |  Right-click Estimator  |  Properties  |  Device Manager  ]


Failure

You will see one of the post-obit errors in Device Director.

In 'Other Devices' the 'USB-Serial Controller' is proceeded by a Xanthous alarm.

Failure

OR

In 'Ports (COM & LPT)' the 'Prolific USB-to-Serial Comm Port (COMx)' volition appear.

Failure

7) Right-click on the entry with the error to open a window and select
"Update driver software..."

Failure

viii) At the beginning Update Driver Software prompt, select
"Scan my computer for driver software".

Failure

9) At the 2d Update Driver Software prompt, select
"Let me choice from a list of device drivers on my computer"

Failure

10) At the third Update Driver Software prompt, gyre downward and select
"Ports (COM & LPT)".

Failure

eleven) At the fourth Update Commuter Software prompt, select
"Prolific USB-to-Serial Comm Port Version: three.two.0.0 [7/31/2007]".

Failure

You should get a prompt saying that the commuter was installed successfully.
You should now meet a properly installed Prolific driver in Device Manger.

Success

Yous can check that the correct version is installed past double-clicking on the Prolific entry in device manager and selecting the Driver tab.

The commuter version shown should exist v3.2.0.0

Success

12) Remove the USB programming cable from your PC then plug the USB programming cable back in.

xiii) (Optional) Reboot your computer.

FAQ ane
Q: My programming cable is not existence recognized.
(Handheld radios using two pin plugs)

a)   "Radio did Non Respond" or
"Radio did Non Ack Programming Style" message appears.
This is a
very common trouble.
Slightly beginning audio jacks could be the problem.

         Make sure the connector is

snapped in all the way .
Some cables
require a really difficult push button to snap in that last ane/xvi inch.

         One indication is that the transmitter may be keyed.
A slight trimming of the cable'due south plug side and edge may be required.

This message appears if the radio is not turned ON while downloading.

b)   "Error has Occurred, Could not open Com Port x"
Each USB slot is connected to a split com port to avoid conflict.
Changing your USB slot will change the COM port number.

c)   "Run-time error 8020: Fault reading from comm device."
Error occurs if Prolific driver version is higher than v3.two.0.0
You must Downgrade to v3.2.0.0

FAQ 2
Q: Why doesn't my new driver work any longer?

A: The driver does not follow the cablevision.  If the cablevision is moved to a dissimilar USB slot, Windows will now load the newest driver to that port. (non 3.2.0.0)

When this occurs, you lot will need to either load commuter iii.2.0.0 to the new USB slot, or plug the cable back into its original USB slot.

You can cheque the driver loaded using the procedure higher up.  Cable


FAQ 3
Q: Is there a quick way to observe my cablevision'due south com port number?

A:   Yes.  Run: Find Com Port    (Windows)


FAQ 4
Q: Afterwards irresolute the com port number of my USB cable in Device Manager, my software reported:
"An error has occurred - could not open port com[n]: (2, 'CreateFile', 'The system cannot find the file specified.')"


A:  After making this change, you must unplug and reinsert your USB programming cablevision for the com port number change to be effective.

Note 1: If you lot are having com port / driver issues, please notation this is Not acquired past your software. It'southward strictly betwixt the PC driver and the cable.

Note 2:
Each USB slot is connected to a separate com port to avoid conflict.
Plugging your cable into a different USB slot will change the com port number and will try to load the Newest Commuter.  Make sure the commuter loaded for the new com port is three.2.0.0
FAQ 5
Q: How do I prevent Windows 7 from automatically installing new drivers?

A:   This solution tin can be constitute at this Microsoft link .
Note:
(This does non apply to Windows 10) .


Build your ain Programming Cable

Here's a project to convert your current cable to 1
using a Silicon Labs CP2012 UART chip.
No driver errors at all.

Build Your Own Cablevision

  My thanks to Jim, KC9HI for his hours of
testing and his input to this page.

73  John 'Miklor'   K3NXU



Uxcell Usb-ppi Plc Programming Cabe Usb to Rs485 Adapter for Siemens S7-200 Driver Software Download

DOWNLOAD HERE

Source: https://www.miklor.com/COM/UV_Drivers.php

Posted by: lejeunemudis1993.blogspot.com

0 Response to "Uxcell Usb-ppi Plc Programming Cabe Usb to Rs485 Adapter for Siemens S7-200 Driver Software Download Updated FREE"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel